top of page
NX-1700H/1800H
  • NX-1700H/1800H

    Features

    • “One Radio” with Multi-protocol Support:
    • Designed to operate under an NXDN or DMR digital,
    • and FM analog protocols
    • Upgradable Digital/Analog mode by software option
    • (no firmware upgrade required)
    • Easy visible, white backlit LCD display:
    • Alphanumeric, 10-digit, 13-character frame
    • (aliases and icons)
    • 7-color LED indicator used to display various radio status
    • Renowned KENWOOD Audio Quality: 6 W (max)loud audio
    • and optimizable TX/RX audio profile: Audio Equalizer, Auto Gain
    • Control (TX/RX) and Microphone type settings
    • Max. 260 Channels per radio, 128 Zones per radio,
    • and 250 Channels per zone
    • Various scan functions: Dual/Single Priority scan,
    • Multi/Single Zone scan and more
    • Orange-colored Emergency button & Customizable
    • Emergency functions
    • Lone Worker
    • Remote Stun, Kill, Check
    • Dual Priority Scan
    • Max/Min Volume setting
    • Voice Announcement
    • Electronic Serial Number (ESN)
    • Display Customization
    • D-sub, 15-pin GPIO and audio connector
    • GPS connectivity
    • Horn Alert and Public Address
    • Ignition Sense
    • 3.5 mm audio jack for external speaker
    • IP54 and MIL-STD 810C/D/E/F/G/H
    • Tech Specs

      SPECIFICATIONS

      General NX-1700H NX-1800H**
      Frequency Range 136-174 MHz 400-470 MHz
      Max. Channels Per Radio 260
      Number of Zones 128
      Max. Channels per Zone 250
      Channel Spacing Analog 12.5/25* kHz
      Digital 6.25/12.5 kHz
      Power Supply 13.6 V DC ±15%
      Current Drain Standby 0.45 A
      RX 2.4 A
      TX 13 A
      Operating Temperature -22ºF to +140ºF (-30ºC to +60ºC)
      Frequency Stability ±0.5 ppm
      Dimensions (W x H x D) Projections Not Included
      6.34 x 1.69 x 6.62 in.
      (161 x 43 x 168.2 mm.)
      Weight Radio 2.67 lbs (1.21 kg)
      FCC ID Type 1 K44517000 K44517100 (Pending)
      Type 2    
      FCC ID Type 1 282F-517000 282F-517100 (Pending)
      Type 2    
      IC Certification 282F-501001 282F-501102
      Receiver NX-1700H NX-1800H**
      Sensitivity NXDN® 6.25 kHz Digital (3% BER) 0.18 μV
      NXDN®12.5 kHz Digital (3% BER) 0.22 μV
      DMR Digital 12 kHz (5% BER) 0.18 µV
      Analog 12 kHz (12dB SINAD) 0.20 μV
      Analog 25 kHz (12dB SINAD) 0.24 μV
      Sensitivity Analog @ 12.5kHz 65 dB
      Analog @ 25kHz 81 dB
      Intermodulation 73 dB
      Spurious Rejection 75 dB
      Audio Distortion 3%
      Audio Output Power 6 W/ 4 W 4 Ω
      Transmitter NX-1700H NX-1800H**
      RF Power Output 50 W / 25 W / 5 W 45 W / 25 W / 5 W
      Spurious Emission -73 dB -75 dB
      FM Hum & Noise Analog @ 12.5kHz 40 dB
      Analog @ 25kHz 50 dB
      Audio Distortion 3%  
      Emission Designator 16K0F3E, 11K0F3E, 8K30F1E, 8K30F1D, 8K30F7W, 4K00F1E, 4K00F1D, 4K00F7W,
      4K00F2D, 7K60FXD, 7K60FXW, 7K60FXE, 7K60F1E, 7K60F1D, 7K60F1W

      *25/30 kHz in VHF/UHF Bands are not included in the models sold in the USA or US territories.
      Analog measurements made per TIA603. Specifications are measured according to applicable standards.
      Specifications shown are typical and subject to change without notice, due to advancements in technology.
      ** Future release

      NXDN® is a registered trademark of JVCKENWOOD Corporation and Icom Inc.
      NEXEDGE® & FleetSync® are a registered trademarks of JVCKENWOOD Corporation.
      All other trademarks are the property of their respective holders.

      MIL-STD & IP

      MIL Standard MIL 810C Methods/Procedures MIL 810D Methods/Procedures MIL 810E Methods/Procedures MIL 810F Methods/Procedures MIL 810G Methods/Procedures MIL 810H Methods/Procedures
      Low Pressure 500.1/Procedure I 500.2/Procedure I, II 500.3/Procedure I, II 500.4/Procedure I, II 500.5/Procedure I, II 500.6/Procedure I, II
      High Temperature 501.1/Procedure I, II 501.2/Procedure I, II 501.3/Procedure I, II 501.4/Procedure I, II 501.5/Procedure I, II 501.7/Procedure I, II
      Low Temperature 502.1/Procedure I 502.2/Procedure I, II 502.3/Procedure I, II 502.4/Procedure I, II 502.5/Procedure I, II 502.7/Procedure I, II
      Temperature Shock 503.1/Procedure I 503.2/Procedure I 503.3/Procedure I 503.4/Procedure I, II 503.5/Procedure I 503.7/Procedure I
      Solar Radiation 505.1/Procedure I 505.2/Procedure I 505.3/Procedure I 505.4/Procedure I 505.5/Procedure I 505.7/Procedure I
      Rain* 506.1/Procedure I, II 506.2/Procedure I, II 506.3/Procedure I, II 506.4/Procedure I, III 506.5/Procedure I, III 506.6/Procedure I, III
      Humidity 507.1/Procedure I, II 507.2/Procedure II, III 507.3/Procedure II, III 507.4 507.5/Prcedure II 507.6/Prcedure II
      Salt Fog 509.1/Procedure I 509.2/Procedure I 509.3/Procedure I 509.4 509.5 509.7
      Dust 510.1/Procedure I 510.2/Procedure I 510.3/Procedure I 510.4/Procedure I, III 510.5/Procedure I 510.7/Procedure I
      Vibration 514.2/Procedure VIII, X 514.3/Procedure I 514.4/Procedure I 514.5/Procedure I 514.6/Procedure I 514.8/Procedure I
      Shock 516.2/Procedure I, II, III, V 516.3/Procedure I, IV, V 516.4/Procedure I, IV, V 516.5/Procedure I, IV, V 516.6/Procedure I, IV, V 516.8/Procedure I, IV, V, VI
      International Protection Standard
      Dust & Water Protection*1 IP54 (per IEC60529) *1 All interfaces must be fully sealed with appropriate covers or by designated genuine accessories