top of page
NX-1700H/1800H

NX-1700H/1800H

Features

  • “One Radio” with Multi-protocol Support:

  • Designed to operate under an NXDN or DMR digital,

  • and FM analog protocols

  • Upgradable Digital/Analog mode by software option

  • (no firmware upgrade required)

  • Easy visible, white backlit LCD display:

  • Alphanumeric, 10-digit, 13-character frame

  • (aliases and icons)

  • 7-color LED indicator used to display various radio status

  • Renowned KENWOOD Audio Quality: 6 W (max)loud audio

  • and optimizable TX/RX audio profile: Audio Equalizer, Auto Gain

  • Control (TX/RX) and Microphone type settings

  • Max. 260 Channels per radio, 128 Zones per radio,

  • and 250 Channels per zone

  • Various scan functions: Dual/Single Priority scan,

  • Multi/Single Zone scan and more

  • Orange-colored Emergency button & Customizable

  • Emergency functions

  • Lone Worker

  • Remote Stun, Kill, Check

  • Dual Priority Scan

  • Max/Min Volume setting

  • Voice Announcement

  • Electronic Serial Number (ESN)

  • Display Customization

  • D-sub, 15-pin GPIO and audio connector

  • GPS connectivity

  • Horn Alert and Public Address

  • Ignition Sense

  • 3.5 mm audio jack for external speaker

  • IP54 and MIL-STD 810C/D/E/F/G/H

  • Tech Specs

    SPECIFICATIONS

    General

    NX-1700H

    NX-1800H**

    Frequency Range

    136-174 MHz

    400-470 MHz

    Max. Channels Per Radio

    260

    Number of Zones

    128

    Max. Channels per Zone

    250

    Channel Spacing

    Analog

    12.5/25* kHz

    Digital

    6.25/12.5 kHz

    Power Supply

    13.6 V DC ±15%

    Current Drain

    Standby

    0.45 A

    RX

    2.4 A

    TX

    13 A

    Operating Temperature

    -22ºF to +140ºF (-30ºC to +60ºC)

    Frequency Stability

    ±0.5 ppm

    Dimensions

    (W x H x D) Projections Not Included

    6.34 x 1.69 x 6.62 in.

    (161 x 43 x 168.2 mm.)

    Weight Radio

    2.67 lbs (1.21 kg)

    FCC ID

    Type 1

    K44517000

    K44517100 (Pending)

    Type 2

     

     

    FCC ID

    Type 1

    282F-517000

    282F-517100 (Pending)

    Type 2

     

     

    IC Certification

    282F-501001

    282F-501102

    Receiver

    NX-1700H

    NX-1800H**

    Sensitivity

    NXDN® 6.25 kHz Digital (3% BER)

    0.18 μV

    NXDN®12.5 kHz Digital (3% BER)

    0.22 μV

    DMR Digital 12 kHz (5% BER)

    0.18 µV

    Analog 12 kHz (12dB SINAD)

    0.20 μV

    Analog 25 kHz (12dB SINAD)

    0.24 μV

    Sensitivity

    Analog @ 12.5kHz

    65 dB

    Analog @ 25kHz

    81 dB

    Intermodulation

    73 dB

    Spurious Rejection

    75 dB

    Audio Distortion

    3%

    Audio Output Power

    6 W/ 4 W 4 Ω

    Transmitter

    NX-1700H

    NX-1800H**

    RF Power Output

    50 W / 25 W / 5 W

    45 W / 25 W / 5 W

    Spurious Emission

    -73 dB

    -75 dB

    FM Hum & Noise

    Analog @ 12.5kHz

    40 dB

    Analog @ 25kHz

    50 dB

    Audio Distortion

    3%

     

    Emission Designator

    16K0F3E, 11K0F3E, 8K30F1E, 8K30F1D, 8K30F7W, 4K00F1E, 4K00F1D, 4K00F7W, 4K00F2D, 7K60FXD, 7K60FXW, 7K60FXE, 7K60F1E, 7K60F1D, 7K60F1W

    *25/30 kHz in VHF/UHF Bands are not included in the models sold in the USA or US territories. Analog measurements made per TIA603. Specifications are measured according to applicable standards. Specifications shown are typical and subject to change without notice, due to advancements in technology. ** Future release

    NXDN® is a registered trademark of JVCKENWOOD Corporation and Icom Inc. NEXEDGE® & FleetSync® are a registered trademarks of JVCKENWOOD Corporation. All other trademarks are the property of their respective holders.

    MIL-STD & IP

    MIL Standard

    MIL 810C Methods/Procedures

    MIL 810D Methods/Procedures

    MIL 810E Methods/Procedures

    MIL 810F Methods/Procedures

    MIL 810G Methods/Procedures

    MIL 810H Methods/Procedures

    Low Pressure

    500.1/Procedure I

    500.2/Procedure I, II

    500.3/Procedure I, II

    500.4/Procedure I, II

    500.5/Procedure I, II

    500.6/Procedure I, II

    High Temperature

    501.1/Procedure I, II

    501.2/Procedure I, II

    501.3/Procedure I, II

    501.4/Procedure I, II

    501.5/Procedure I, II

    501.7/Procedure I, II

    Low Temperature

    502.1/Procedure I

    502.2/Procedure I, II

    502.3/Procedure I, II

    502.4/Procedure I, II

    502.5/Procedure I, II

    502.7/Procedure I, II

    Temperature Shock

    503.1/Procedure I

    503.2/Procedure I

    503.3/Procedure I

    503.4/Procedure I, II

    503.5/Procedure I

    503.7/Procedure I

    Solar Radiation

    505.1/Procedure I

    505.2/Procedure I

    505.3/Procedure I

    505.4/Procedure I

    505.5/Procedure I

    505.7/Procedure I

    Rain*

    506.1/Procedure I, II

    506.2/Procedure I, II

    506.3/Procedure I, II

    506.4/Procedure I, III

    506.5/Procedure I, III

    506.6/Procedure I, III

    Humidity

    507.1/Procedure I, II

    507.2/Procedure II, III

    507.3/Procedure II, III

    507.4

    507.5/Prcedure II

    507.6/Prcedure II

    Salt Fog

    509.1/Procedure I

    509.2/Procedure I

    509.3/Procedure I

    509.4

    509.5

    509.7

    Dust

    510.1/Procedure I

    510.2/Procedure I

    510.3/Procedure I

    510.4/Procedure I, III

    510.5/Procedure I

    510.7/Procedure I

    Vibration

    514.2/Procedure VIII, X

    514.3/Procedure I

    514.4/Procedure I

    514.5/Procedure I

    514.6/Procedure I

    514.8/Procedure I

    Shock

    516.2/Procedure I, II, III, V

    516.3/Procedure I, IV, V

    516.4/Procedure I, IV, V

    516.5/Procedure I, IV, V

    516.6/Procedure I, IV, V

    516.8/Procedure I, IV, V, VI

    International Protection Standard

    Dust & Water Protection*1

    IP54 (per IEC60529)

    *1 All interfaces must be fully sealed with appropriate covers or by designated genuine accessories

bottom of page